Open Access   Article Go Back

An Experimental Investigation on Strength Behaviour of Concrete by Partial Replacement of Fine Aggregate with Copper Slag and Cement With Silica Fume

Abdullah Anwar1 , Syed Aqeel Ahmad2

  1. Department of Civil Engineering, Integral University, Lucknow, India.
  2. Department of Civil Engineering, Integral University, Lucknow, India.

Correspondence should be addressed to: a.anwar14330@gmail.com.

Section:Research Paper, Product Type: Journal Paper
Volume-6 , Issue-1 , Page no. 177-185, Jan-2018

CrossRef-DOI:   https://doi.org/10.26438/ijcse/v6i1.177185

Online published on Jan 31, 2018

Copyright © Abdullah Anwar, Syed Aqeel Ahmad . This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

View this paper at   Google Scholar | DPI Digital Library

How to Cite this Paper

  • IEEE Citation
  • MLA Citation
  • APA Citation
  • BibTex Citation
  • RIS Citation

IEEE Style Citation: Abdullah Anwar, Syed Aqeel Ahmad, “An Experimental Investigation on Strength Behaviour of Concrete by Partial Replacement of Fine Aggregate with Copper Slag and Cement With Silica Fume,” International Journal of Computer Sciences and Engineering, Vol.6, Issue.1, pp.177-185, 2018.

MLA Style Citation: Abdullah Anwar, Syed Aqeel Ahmad "An Experimental Investigation on Strength Behaviour of Concrete by Partial Replacement of Fine Aggregate with Copper Slag and Cement With Silica Fume." International Journal of Computer Sciences and Engineering 6.1 (2018): 177-185.

APA Style Citation: Abdullah Anwar, Syed Aqeel Ahmad, (2018). An Experimental Investigation on Strength Behaviour of Concrete by Partial Replacement of Fine Aggregate with Copper Slag and Cement With Silica Fume. International Journal of Computer Sciences and Engineering, 6(1), 177-185.

BibTex Style Citation:
@article{Anwar_2018,
author = {Abdullah Anwar, Syed Aqeel Ahmad},
title = {An Experimental Investigation on Strength Behaviour of Concrete by Partial Replacement of Fine Aggregate with Copper Slag and Cement With Silica Fume},
journal = {International Journal of Computer Sciences and Engineering},
issue_date = {1 2018},
volume = {6},
Issue = {1},
month = {1},
year = {2018},
issn = {2347-2693},
pages = {177-185},
url = {https://www.ijcseonline.org/full_paper_view.php?paper_id=1655},
doi = {https://doi.org/10.26438/ijcse/v6i1.177185}
publisher = {IJCSE, Indore, INDIA},
}

RIS Style Citation:
TY - JOUR
DO = {https://doi.org/10.26438/ijcse/v6i1.177185}
UR - https://www.ijcseonline.org/full_paper_view.php?paper_id=1655
TI - An Experimental Investigation on Strength Behaviour of Concrete by Partial Replacement of Fine Aggregate with Copper Slag and Cement With Silica Fume
T2 - International Journal of Computer Sciences and Engineering
AU - Abdullah Anwar, Syed Aqeel Ahmad
PY - 2018
DA - 2018/01/31
PB - IJCSE, Indore, INDIA
SP - 177-185
IS - 1
VL - 6
SN - 2347-2693
ER -

VIEWS PDF XML
770 567 downloads 278 downloads
  
  
           

Abstract

Concrete is the most widely used building material in civil engineering industry throughout the globe because of its high structural strength and constancy, where the fine aggregate is generally natural sand. The usage of sand in construction activity results in the excessive mining, causing depletion of natural resources resulting increase in scour depth and sometimes flood possibility. Copper Slag waste is most usually made from the copper industry, whereas Silica Fume is a by-product from many manufactures. Chuck out of both copper slag waste and Silica Fume is one of the major environmental problems worldwide today. Hence the reuse of waste material has been emphasized to sustainable growth. This research paper presents a study of the Strength properties of concrete by partial replacement of fine aggregate with copper slag and cement with silica fume. In the present Experimental Investigation, for M40 grade of concrete, fine aggregate (River Sand) was partially replaced with Copper Slag (40%) and cement was partially replaced with Silica Fume from 5% to 15% at an interval of 5%. This research gives a detailed observational study on Compressive strength, split tensile strength, flexural strength at age of 28 days. Test results indicate that the strength properties of concrete were improved having copper slag as a partial replacement of Sand (up to 40%) and Silica fume as a partial replacement of cement (up to 10%).

Key-Words / Index Term

Copper Slag, Compressive strength, Flexural Strength, Silica Fume, Split tensile strength

References

[1] Bayasi, Zing, Zhou, Jing, (1993) “Properties of Silica Fume Concrete and Mortar”, ACI Materials Journal 90 (4) 349 – 356
[2]. Leema Rose. A & Suganya, P. (2015) Performance of Copper Slag on Strength and Durability Properties as Partial Replacement of Fine Aggregate in Concrete. International Journal of Emerging Technology and Advanced Engineering. 5 (1).
[3] K.Srinivasu. (n.d.). A study on compressive strength properties and effects of copper slag as partial replacement of fine aggregate in concrete. ELK Asia Pacific Journals.
[4] Singh, H. (2015). Use of copper slag as fine aggregate ‐ A case study. International journal of innovations in engineering research and technology, 2(5), 1-7
[5] Patil, M. V. (2016). Performance of Copper Slag as Sand Replacement in Concrete. International Journal of Applied Engineering Research, 11(6), 4349-4353
[6] Arivalagan.S. (2013). Experimental Study on the Flexural Behavior of Reinforced Concrete Beams as Replacement of Copper Slag as Fine Aggregate. Journal of Civil Engineering and Urbanism, 3(4), .176-182
[7] M.Maheswari, M. (2016). Mechanical and Durability Properties of RC Beams Using Copper Slag as Fine Aggregate in Concrete. International Research Journal of Engineering and Technology, 3(3)
[8] Madhavi,T.C. Effect of Copper Slag on the Mechanical Strengths of Concrete. International Journal of ChemTech Research, 8(12), 442-449,2015.
[9] Nataraja, M. C. Concrete mix design using copper slag as fine aggregate. International journal of civil engineering, 5(9), 90-99, 2014.
[10] Amudhavalli, N. K. & Mathew, J. (2012). Effect of silica fume on strength and durability parameters of concrete. International Journal of Engineering Sciences & Emerging Technologies. 3 (1), 28-35
[11] K., Sundararajan , R. ( 2004). Effect of partial replacement of cement with silica fume on the strength and durability characteristics of High performance concrete. 29th Conference on our world in concrete & structures: 25 - 26 August 2004, Singapore
[12] Ghutke, V. S. & Bhandari, P.S. (2014). Influence of silica fume on concrete. IOSR Journal of Mechanical and Civil Engineering, 44-47
[13] Hanumesh B. M., Varun, B. K. & Harish B. A.(2015).The Mechanical Properties of Concrete Incorporating Silica Fume as Partial Replacement of Cement. International Journal of Emerging Technology and Advanced Engineering. 5 (9), 270
[14] Sasikumar, A. (2016). Experimental Investigation on Properties of Silica Fumes as a Partial Replacement of Cement. International Journal of Innovative Research in Science,, 5 (3), 4392-4395
[15] Sharma, a. &Seema (2012). Effect of partial replacement of cement with silica fume on compressive strength of concrete. International journal of research in technology and management, 1 (1), 34-36.
[16] IS: 8112-1989, 43 Grade Ordinary Portland cement—Specification, Bureau of Indian Standards, New Delhi.
[17] BIS 383: 1970 Course and fine aggregate from natural sources for concrete 9th Revision, BIS, New Delhi, 1970.
[18] IS 10262 (2009) Indian Recommended guidelines for concrete mix design.
[19] Abdullah Anwar, Sabih Ahmad, S. Mohd. Ashraf Husain and Syed Aqeel Ahmad, 2015. “Salvage of Ceramic Waste and Marble Dust for the Refinement of Sustainable Concrete”. International Journal of Civil Engineering & Technology (IJCIET). Volume:6, Issue:9, pages:79-92
[20] IS 4031-3 (1988): Methods of Physical test for hydraulic cement, Part 3: Determination of soundness [CED 2: Civil Engineering]
[21] IS 650 (1991): Specification for standard sand for testing of cement [CED 2: Cement and Concrete]
[22] IS 383 (1970): Specification for Coarse and fine Aggregate from Natural Sources for Concrete [CED 2: Cement and Concrete]
[23] IS 9103 (1999): Specifications for concrete for admixtures - [CED 2: Cement and Concrete]
[24] Abhinav Shyam, Abdullah Anwar, Syed Aqeel Ahmad, "Experimental Study on the Behavior of Copper Slag as Partial Replacement of Fine Aggregate in Concrete", Volume 5, Issue IV, International Journal for Research in Applied Science and Engineering Technology (IJRASET), ISSN: 2321-9653, pp 1465-1474.
[25] IS 456 (2000): Plain and Reinforced Concrete – Code of practice [CED 2: Cement and Concrete]
[26] IS 2386-1 (1963): Methods of Test of Aggregates for Concrete, Part I: Particle Size and Shape [CED 2: Cement and Concrete]