Design of Continuous Mode Hybrid Standalone Power Station with Hybrid Controller to Select the Best Optimal Power Flow
Arpan Dwivedi1 , Yogesh Pahariya2
- Department of Electrical Engineering, RKDFIST, SRK University, Bhopal, India.
- Department of Electrical Engineering, RKDFIST, SRK University, Bhopal, India.
Correspondence should be addressed to: arpandwvd@gmail.com.
Section:Research Paper, Product Type: Journal Paper
Volume-6 ,
Issue-2 , Page no. 275-277, Feb-2018
CrossRef-DOI: https://doi.org/10.26438/ijcse/v6i2.275277
Online published on Feb 28, 2018
Copyright © Arpan Dwivedi, Yogesh Pahariya . This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
View this paper at Google Scholar | DPI Digital Library
How to Cite this Paper
- IEEE Citation
- MLA Citation
- APA Citation
- BibTex Citation
- RIS Citation
IEEE Style Citation: Arpan Dwivedi, Yogesh Pahariya, “Design of Continuous Mode Hybrid Standalone Power Station with Hybrid Controller to Select the Best Optimal Power Flow,” International Journal of Computer Sciences and Engineering, Vol.6, Issue.2, pp.275-277, 2018.
MLA Style Citation: Arpan Dwivedi, Yogesh Pahariya "Design of Continuous Mode Hybrid Standalone Power Station with Hybrid Controller to Select the Best Optimal Power Flow." International Journal of Computer Sciences and Engineering 6.2 (2018): 275-277.
APA Style Citation: Arpan Dwivedi, Yogesh Pahariya, (2018). Design of Continuous Mode Hybrid Standalone Power Station with Hybrid Controller to Select the Best Optimal Power Flow. International Journal of Computer Sciences and Engineering, 6(2), 275-277.
BibTex Style Citation:
@article{Dwivedi_2018,
author = {Arpan Dwivedi, Yogesh Pahariya},
title = {Design of Continuous Mode Hybrid Standalone Power Station with Hybrid Controller to Select the Best Optimal Power Flow},
journal = {International Journal of Computer Sciences and Engineering},
issue_date = {2 2018},
volume = {6},
Issue = {2},
month = {2},
year = {2018},
issn = {2347-2693},
pages = {275-277},
url = {https://www.ijcseonline.org/full_paper_view.php?paper_id=1738},
doi = {https://doi.org/10.26438/ijcse/v6i2.275277}
publisher = {IJCSE, Indore, INDIA},
}
RIS Style Citation:
TY - JOUR
DO = {https://doi.org/10.26438/ijcse/v6i2.275277}
UR - https://www.ijcseonline.org/full_paper_view.php?paper_id=1738
TI - Design of Continuous Mode Hybrid Standalone Power Station with Hybrid Controller to Select the Best Optimal Power Flow
T2 - International Journal of Computer Sciences and Engineering
AU - Arpan Dwivedi, Yogesh Pahariya
PY - 2018
DA - 2018/02/28
PB - IJCSE, Indore, INDIA
SP - 275-277
IS - 2
VL - 6
SN - 2347-2693
ER -
VIEWS | XML | |
746 | 445 downloads | 359 downloads |
Abstract
In this paper design of continuous mode Hybrid Stand alone power station with battery and Diesel generator is modelled. The controller is designed to maximize the usage of energy sources and reduces the use of diesel generator. The state of battery charging is maintained. This paper firstly focuses on design of hybrid power station is to full fill load demand. Secondly a relay based controller is designed to select the best optimal power output as per availability of sources to minimize the use of Diesel generator and Battery operation. A supervisor control modes are further discussed for hybrid controller as per the load demand.
Key-Words / Index Term
Diesel Generator(DG), Hybrid Controller,Supervisory control, Wind turbine Generator(WTG)
References
[1] Meinhardt, M and Cramer, G. "Past, Present and Future of grid connected Photovoltaic and Hybrid PowerSystems". IEEE Power Engineering Society Summer Meeting. Vol. 2, pp. 1283 -1288, July 2000.
[2] Chang, Liuchen. "Wind Energy conversion Systems". Canadian Review. pp. 12-16, 2002.
[3] Ross, M, Turcotte, D and Roussin, S. "Comparison of AC, DC, and AC/DC bus configurations for PV Hybrid Systems". SESCI Conference. 2005.
[4] Wright, Alan D. "Modern Control Design for Flexible Wind Turbines". Technical Report on National Renewable Energy Laboratory (NREL). pp. 1223, July 2004
[5] Valenciaga, F and Puleston, P F. "Supervisor control for standalone hybrid power system using wind and photovoltaic energy".IEEE transaction Energy Conversion. Vol. 20. No2, pp. 398- 405,June 2005.
[6] De Lemos Pereira, Alexandre. "Modular Supervisory Controller for Hybrid Power Systems".
[4] Phd. Thesis. Riso National Laboratory, Roskilde. University of Denmark, June 2000.
[5] Roscia, M and Zaninelli, D. "Sustainability and quality through solar electric energy". 10th International conference on Harmonics and quality of Power. Vol. 2, pp. 782 - 792, 2002.
[6] Ross, M and Turcotte, D. "Bus configuration in Hybrid Systems". Hybrid info Semiannual newsletter on photovoltaic hybrid power systems in Canada. 7, pp. 25, Summer 2004.
[7] Meinhardt, M and Cramer, G. "Past, Present and Future of grid connected Photovoltaic and Hybrid PowerSystems". IEEE Power Engineering Society Summer Meeting. Vol.2, pp. 1283 -1288, July 2000.