Open Access   Article Go Back

Paramerter Monitoring of Induction motor : A Review

Shefali Jamwal1 , Shimi Sudha Letha2

Section:Review Paper, Product Type: Journal Paper
Volume-6 , Issue-6 , Page no. 1441-1446, Jun-2018

CrossRef-DOI:   https://doi.org/10.26438/ijcse/v6i6.14411446

Online published on Jun 30, 2018

Copyright © Shefali Jamwal, Shimi Sudha Letha . This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

View this paper at   Google Scholar | DPI Digital Library

How to Cite this Paper

  • IEEE Citation
  • MLA Citation
  • APA Citation
  • BibTex Citation
  • RIS Citation

IEEE Style Citation: Shefali Jamwal, Shimi Sudha Letha, “Paramerter Monitoring of Induction motor : A Review,” International Journal of Computer Sciences and Engineering, Vol.6, Issue.6, pp.1441-1446, 2018.

MLA Style Citation: Shefali Jamwal, Shimi Sudha Letha "Paramerter Monitoring of Induction motor : A Review." International Journal of Computer Sciences and Engineering 6.6 (2018): 1441-1446.

APA Style Citation: Shefali Jamwal, Shimi Sudha Letha, (2018). Paramerter Monitoring of Induction motor : A Review. International Journal of Computer Sciences and Engineering, 6(6), 1441-1446.

BibTex Style Citation:
@article{Jamwal_2018,
author = {Shefali Jamwal, Shimi Sudha Letha},
title = {Paramerter Monitoring of Induction motor : A Review},
journal = {International Journal of Computer Sciences and Engineering},
issue_date = {6 2018},
volume = {6},
Issue = {6},
month = {6},
year = {2018},
issn = {2347-2693},
pages = {1441-1446},
url = {https://www.ijcseonline.org/full_paper_view.php?paper_id=2365},
doi = {https://doi.org/10.26438/ijcse/v6i6.14411446}
publisher = {IJCSE, Indore, INDIA},
}

RIS Style Citation:
TY - JOUR
DO = {https://doi.org/10.26438/ijcse/v6i6.14411446}
UR - https://www.ijcseonline.org/full_paper_view.php?paper_id=2365
TI - Paramerter Monitoring of Induction motor : A Review
T2 - International Journal of Computer Sciences and Engineering
AU - Shefali Jamwal, Shimi Sudha Letha
PY - 2018
DA - 2018/06/30
PB - IJCSE, Indore, INDIA
SP - 1441-1446
IS - 6
VL - 6
SN - 2347-2693
ER -

VIEWS PDF XML
653 361 downloads 270 downloads
  
  
           

Abstract

A continuous parameter monitoring of machine is required in certain applications where failure of machine leads to loss of quality control, productivity and safety against catastrophic failure. Machine faults are often linked to the bearing faults. Parameter monitoring of machine involves continuous assessment on the performance of rotating components i.e. bearings, gears and motors and predicting the faults before it cause any adversity. Rotating machines are commonly used in the industry for different applications such as railways, pumps, conveyors, blowers, elevator, mining industry, etc. Parameter monitoring of rotating machines has been an important task for technicians, engineers, and researchers mainly in industrial application. This paper presents an enlarged survey on the expansion and the recent approaches in the parameter monitoring of rotating machines. In current scenario, parameter monitoring proved their ability for fault detection of incipient faults in electrical machines and equipment. Several techniques such as vibration monitoring, acoustic emission monitoring, invasive monitoring, oil monitoring are available for determining the health of rotating machines but all these monitoring methods needs expensive transducers and sensors.

Key-Words / Index Term

Condition monitoring, fault detection, wireless monitoring, motor currrent signature analysis

References

[1] Tarek Aroui, Yassine Koubaa, and Ahm Toumi, “Magnetic Coupled Circuit Modelling of Induction manchies oriented to Diagnostics”, Leonardo Journal of sciences, issue 13, pp.103- 121, Dec.2008.
[2] Mohamed Boucherma, Kaikaa, and Khezzar, “Park Model of squirrel cage Induction Machine including space harmonic effects”, Journal of Electrical Engineering, pp. 193-199, 2006.
[3] Mark M. Hodowanec, William R.Finiey, Scott and W. Kreitzer, “Motor field protection and recommended settings and monitoring”, IEEE.pp. 271-284, 2002.
[4] C.M. Riley, B.K. Lin, T.G. Habetler and G.B. Kliman, “Stator Current Harmonics and their Causal Vibrations: A Preliminary Investigation of Sensorless Vibration Monitoring Applications,” IEEE Trans. on Ind. Appl., vol. 35, no. 1, pp. 94-99, Jan./Feb. 1999.
[5] M.Y.Chow, Robert N Sharpe and James C Hung, “ On the Application and Design of Artificial Neural Networks for motor fault detection – Part I”, IEEE Transactions on Industrial Electronics, Vol. 40, No 2 , pp 181- 188, April 1993.
[6] P.V.Goode, M.Y.Chow, “Using a Neural/Fuzzy system to extract Heuristic knowledge of incipient faults in I.M: part IMethodology”, IEEE transactions on industrial Electronics, Vol. 42, No.2, 131-138, April 1995.
[7] J. F. Martins, V. Fernao Pires, and A. J. Pires,“ Unsupervised Neural-Network-Based Algorithm for an On-Line Diagnosis of Three- Phase Induction Motor Stator Fault”, IEEE Transactions On Industrial Electronics, Vol. 54, NO. 1, February, pp. 259-264, 2007.
[8] Y. Han and Y. H. Song, "CM techniques for electricalequipment: a literature survey," IEEE Power Engineering Review, vol.22, pp. 59-59, 2002.
[9] P. Tavner, ”Review of condition monitoring of rotating electrical machines," IET Electric Power Applications, vol. 2, no. 4, pp. 215-247, 2008.
[10] O. Duque-Perez, D. Morinigo-Sotelo, and M. Perez- Alonso, "Diagnosisof induction motors fed by supplies with high harmonic content usingmotor current signature analysis," International Conference on PowerEngineering, Energy and Electrical Drives, pp. 1- 6, 2011.
[11] W. T. Thomson and M. Fenger, "Case histories of current signatureanalysis to detect faults in induction motor drives," IEEE InternationalElectric Machines and Drives Conference, vol.3, pp. 1459-1465, 2003.
[12] J. Ilonen, J.-K. Kamarainen, T. Lindh, J. Ahola, H. Kalviainen, and J. Partanen, Diagnosis tool for motor condition monitoring," IEEE Transactions on Industry Applications, vol. 41, no. 4, pp. 963{971, 2005.
[13] R. R. Schoen, T. G. Habetler, F. Kamran, and R. G. Bartfield, "Motorbearing damage detection using stator current monitoring," IEEETransactions on Industry Applications, vol. 31, pp. 1274-1279, 1995.
[14] C. Ranga and A. K. Chandel, “Advanced tool based condition monitoring of induction machines by using labviewa review," in Electrical Computer and Electron- ics (UPCON), 2015 IEEE UP Section Conference on pp. 1-6, IEEE, 2015.
[15] Y. Han, Y.H. Song. CM techniques for electrical equipment—A literature survey. IEEE Trans. Power Deliv. Vol. 18, pp. 4-13, 2003.
[16] J. L. H. Silva and A. J. M. Cardoso, "Bearing failures diagnosis in three phase induction motors by extended Park`s vector approach," 31st Annual Conference of IEEE Industrial Electronics Society, pp. 6 , 2005.
[17] J. R. Stack, T. G. Habetler, and R. G. Harley, "Fault classification andfault signature production for rolling element bearings in electricmachines," IEEE Transactions on Industry Applications, vol. 40, pp.735- 739, 2004.
[18] C. Bianchini, F. Immovilli, M. Cocconcelli, R. Rubini, and A. Bellini,"Fault detection of linear bearings in brushless ac linear motors byvibration analysis," IEEE Transactions on Industrial Electronics, vol.58, pp. 1684- 1694, 2011.
[19] M. E. H. Benbouzid, "A review of induction motors signature analysisas a medium for faults detection," Proceedings of the 24th AnnualConference of the IEEE Industrial Electronics Society, vol.4, pp. 1950-1955, 1998.
[20] M. Pineda-Sanchez, R. Puche-Panadero, M. Riera- Guasp, A. Sapena-Bano, J. Roger-Folch, and J. Perez- Cruz, "Motor CMof induction motor with programmable logic controller and industrialnetwork," Proceedings of the 2011-14th European Conference onPower Electronics and Application, pp. 1-10, 2011.
[21] G. Singh and S. A. S. Al Kazzaz, “Induction machine drive condition monitoring and diagnostic researcha survey, Electric Power Systems Research, vol. 64, no. 2, pp. 145-158, 2003.
[22] W. Li and C. K. Mechefske, Detection of induction motor faults: a comparison of stator current, vibration and acoustic methods," Journal of vibration and Control, vol. 12, no. 2, pp. 165{188, 2006.
[23] V. Patel, N. Tandon, and R. Pandey, “Defect detectio in deep groove ball bearing in presence of external vibration using envelope analysis and duffing oscillator," Measurement, vol. 45, no. 5, pp. 960{970, 2012.
[24] C. Vaithilingam and G. Thio, “Health monitoring of induction motor for vibration," Journal of Electrical Engineering, pp. 1-8, 2015.
[25] A.K.Verma, S. Sarangi, and M.H. Kolekar. Misalignment fault detection in induction motor using rotor shaft vibration and stator current signature analysis. International Journal of Mechatronics and Manufacturing Systems, vol. 6(5-6), pp.422-436, 2013.
[26] R. Shnibha, A. Albarbar, A. Abouhnik and G. Ibrahim. A more reliable method for monitoring the condition of three-phase induction motors based on their vibrations. ISRN Mechanical Engineering, 2012.
[27] I. Sudhakar, S. AdiNarayana and M. AnilPrakash. Condition Monitoring of a 3-Ø Induction Motor by Vibration Spectrum anaylsis using Fft Analyser-A Case Study. Materials Today: Proceedings, vol. 4(2), pp.1099-1105, 2017.
[28] A. Ruiz-Gonzalez, F. Vargas-Merino, “Application of Slope PWM Strategies to Reduce Acoustic Noise Radiated by Inverter-Fed Induction Motors,” in IEEE Trans. on Industrial Electronics, vol. 60(7), pp. 2555-2563, 2013.
[29] A.G. Garcia-Ramirez, L.A. Morales-Hernandez, R.A. Osornio-Rios, A. Garcia-Perez and R.J. Romero-Troncoso. Thermographic technique as a complement for MCSA in induction motor fault detection. In Electrical Machines (ICEM), 2014 International Conference on (pp. 1940-1945). IEEE, 2014.
[30] Y. Park, M. Jeong, S.B. Lee, J.A. Antonino-Daviu and M. Teska. Influence of blade pass frequency vibrations on MCSA-based rotor fault detection of induction motors. IEEE Transactions on Industry Applications, vol. 53(3), pp. 2049-2058, 2017.
[31] S. Haus, H. Mikat and M. Nowara, S. T. Kandukuri, U. Klingauf, and M. Buderath: Fault Detection based on MCSA for a 400Hz Asynchronous Motor for Airborne Applications, International Journal of Prognostics and Health Management, 2013
[32] A. Singhal and M. A. Khandekar, “Bearing fault detection in induction motor using motor current signature analysis”, International Journal of Advanced Research in Electrical, Electronics and Instrumentation Engineering, vol. 2, no. 7, pp. 3258–3264, 2013.
[33] S.S. Tijare, G.D. Thakare, R.P. Argelwar. “Multi-purpose DC high voltage generator using CockcroftWalton voltage multiplier circuit” International Journal for scientific Research and development, vol. 2(12), 2015.
[34] M. Nikhil, R. Waghamare, P. Argelwar, A. Thakare and S. Urkude. “Battery Operated Multistage High voltage generation by using CockcroftWalton multiplier,” International Journal of Engineering Sciences & Research Technology, vol. 4(3) 2015
[35] R.S. Marino, S. Peresada and P. Valigi, ‘‘Adaptive Input-Output Linearizing Control of Induction Motor’’, IEEE Transaction on Automatic Control, vol. 38(2), pp. 208-221, 2014.
[36] A. Glowacz and Z. Glowacz, “Diagnosis of the three-phase induction motor using thermal imaging,” Infrared Phys. Technol., vol. 81, pp. 7–16, 2017.
[37] A. G. Garcia-Ramirez, L. A. Morales-Hernandez, R. A. Osornio-Rios, J. P. Benitez-Rangel, A. Garcia-Perez, and R. D. J. Romero-Troncoso, “Fault detection in induction motors and the impact on the kinematic chain through thermographic analysis,” Electr. Power Syst. Res., vol. 114, pp. 1–9, 2014.
[38] G. T. Singh, C. Anil Kumar, and V. N. A. Naikan, “Induction motor inter turn fault detection using infrared thermographic analysis,” Infrared Phys. Technol., vol. 77, pp. 277–282, 2016.
[39] V. V. Thomas, K. Vasudevan, and V. J. Kumar, “Use of air-gap torque spectra for squirrel cage rotor fault identification”, 4th IEEE Int. Conf. PIower Electron. Drive Syst. IEEE PEDS 2001 - Indones. Proc. (Cat. No.01TH8594), India, vol. 2, pp. 484– 488, 2001.
[40] A. M. da Silva, R. J. Povinelli, and N. A. Demerdash, “Rotor bar fault monitoring method based on analysis of air-gap torques of induction motors”, IEEE Transactions on Industrial Informatics, vol. 9(4), pp. 2274– 2283, 2013.
[41] A. Ruiz-Gonzalez, F. Vargas-Merino, “Application of Slope PWM Strategies to Reduce Acoustic Noise Radiated by Inverter-Fed Induction Motors,” in IEEE Trans. on Industrial Electronics, vol. 60(7), pp. 2555-2563, 2013.
[42] C.G. Nistor, “Analysis of noise and heating for three-phase induction motor fed by inverter,” Proc. of the 14th International Conference on Optimization of Electrical and Electronic Equipment, Braşov, Romania, pp. 389-396, 2014. [Online]. Available: http://dx.doi.org/ 10.1109/OPTIM.2014.6850931.
[43] S.A. Mortazavizadeh, A. Vahedi and A. Zohouri. "Detection of Stator Winding Inter-turn Short Circuit In Induction Motor Using Vibration Specified Harmonic Amplitude", 2nd International Conference on Acoustics & Vibration (ISAV2012), Tehran, Iran, 26-27 Dec. 2012.
[44] F. Filipetti, G. Franceschini, C. Tassoni, and P. Vas, “EAI techniques in induction machine diagnosis including the speed ripple effect,” IEEE Transactions India Applications, vol. 34(1), pp.98-108, 1998.
[45] J.R. Mountain, “Fuzzy logic Motor Speed Control with Real-Time interface using 8-bit Embedded Processor,” 42nd South Eastern Symposium on System Theory, March 2010.
[46] F. Rashidi. Sensorless speed sontrol of induction motor drives using robust and adaptive neuro-fuzzzy based intelligent controller”,IEEE international conference on industrial technology (ICIT), pp. 617- 627, 2004.
[47] L. Frosini, A. Borin, L. Girometta et al., "A novel approach to detect short circuits in low voltage induction motor by stray flux measurement", Proc. Int. Conf. Electrical Machines (ICEM), pp. 1538-1544, 2012.
[48] L.P.C.M. Filho, R. Pederiva, J.N. Brito, "Detection of stator winding faults in induction machines using flux and vibration analysis", Mech. Syst. Signal Process., vol. 42(1), pp. 377-387, 2014.
[49] R. Romary, R. Pusca, J.P. Lecointe et al., "Electrical machines fault diagnosis by stray flux analysis", Proc. Int. Conf. Electrical Machines Design Control and Diagnosis (Wemdcd), pp. 247-256, 2013