Hybrid Power System for Power Quality Improvement and Security Analysis
Ajay Kumar Mishra1 , Bharat Mishra2 , A. K. Sharma3
Section:Research Paper, Product Type: Journal Paper
Volume-07 ,
Issue-10 , Page no. 107-110, May-2019
CrossRef-DOI: https://doi.org/10.26438/ijcse/v7si10.107110
Online published on May 05, 2019
Copyright © Ajay Kumar Mishra, Bharat Mishra, A. K. Sharma . This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
View this paper at Google Scholar | DPI Digital Library
How to Cite this Paper
- IEEE Citation
- MLA Citation
- APA Citation
- BibTex Citation
- RIS Citation
IEEE Style Citation: Ajay Kumar Mishra, Bharat Mishra, A. K. Sharma, “Hybrid Power System for Power Quality Improvement and Security Analysis,” International Journal of Computer Sciences and Engineering, Vol.07, Issue.10, pp.107-110, 2019.
MLA Style Citation: Ajay Kumar Mishra, Bharat Mishra, A. K. Sharma "Hybrid Power System for Power Quality Improvement and Security Analysis." International Journal of Computer Sciences and Engineering 07.10 (2019): 107-110.
APA Style Citation: Ajay Kumar Mishra, Bharat Mishra, A. K. Sharma, (2019). Hybrid Power System for Power Quality Improvement and Security Analysis. International Journal of Computer Sciences and Engineering, 07(10), 107-110.
BibTex Style Citation:
@article{Mishra_2019,
author = {Ajay Kumar Mishra, Bharat Mishra, A. K. Sharma},
title = {Hybrid Power System for Power Quality Improvement and Security Analysis},
journal = {International Journal of Computer Sciences and Engineering},
issue_date = {5 2019},
volume = {07},
Issue = {10},
month = {5},
year = {2019},
issn = {2347-2693},
pages = {107-110},
url = {https://www.ijcseonline.org/full_spl_paper_view.php?paper_id=984},
doi = {https://doi.org/10.26438/ijcse/v7i10.107110}
publisher = {IJCSE, Indore, INDIA},
}
RIS Style Citation:
TY - JOUR
DO = {https://doi.org/10.26438/ijcse/v7i10.107110}
UR - https://www.ijcseonline.org/full_spl_paper_view.php?paper_id=984
TI - Hybrid Power System for Power Quality Improvement and Security Analysis
T2 - International Journal of Computer Sciences and Engineering
AU - Ajay Kumar Mishra, Bharat Mishra, A. K. Sharma
PY - 2019
DA - 2019/05/05
PB - IJCSE, Indore, INDIA
SP - 107-110
IS - 10
VL - 07
SN - 2347-2693
ER -
Abstract
The generation of electricity through renewable sources has exponentially increased in recent years in response to environmental pollution caused by fossil fuels. When we talk about renewable energy is difficult not to refer to solar energy, wind energy, biomass energy and Pedal generation due to its high rate of growth compared to their peers and potential. This is associated with the fact that the government is implementing a process of changing the production of energy and country`s energy matrix where one of the fundamental pillars is to eliminate dependence on fossil resources and promote the use of renewable energy especially for rural areas. Therefore, this makes clear that it is important and needed to study the effects and possible problems related to renewable energy that entails the use of photovoltaic systems connected to the network with hybrid one like pedal system generation which is easily available. In this context, the work focuses on power quality by connecting photovoltaic to low-power electrical system with using solar and pedal generation simultaneously. Objective of this research based on other sources of energy i.e. renewable energy, because we have limited sources of non renewable sources of energy i. e. coal diesel, petrol etc. Energy crises need to search for other source of energy that is specifically renewable energy. Human power praise is more because of health benefit as a source of energy. And in this peoples are more aware to his health point of view. More effective use of human power could be achieved through properly design approach. Human power as prime mover used to operate working unit is termed as human powered machine (bicycle) and this machine is different from conventional bicycle because it can operate with different arrangement with the help of hand or leg or in special case with the help of animal power and in developed machine combination of gear arrangement and chain are used. In this paper two models are simulated one for solar energy and other for pedal energy both are the alternate sources of energy and easily available. In the developed system energy security is also maintained with continuity of supply with safe operation
Key-Words / Index Term
Power Quality, Power Filter, power electronic Controller, Harmonics Compensation, Total Harmonic Distortion
References
[1] Wilson, D. G., (1986), Understanding Pedal Power, Technical paper 51, ISBN: 0-86619-268-9.
[2] Dwari S. and Parsa L., (2011), An Efficient High-Step-Up Interleaved DC–DC Converter With A Common Active Clamp,, IEEE Trans. Power Electron. 26(1) 66-78.
[3] Saurabh, Dr. Saha P.K., Dr. Panda G.K., ,A High Step Up Boost Converter Using Coupled Inductor With PI Control,, IJAREEIE, 4(1), 329-336.
[4] Murali Krishna R.L., (2014), Simulation Of An Efficient Hybrid Transformer DC-DC Converter For PV Based Renewable Energy Sources-Power Conditioning Systems (PCS) Applications With High Boost Ratio, IJSEAT, 2(9), 364-378.
[5] Martin, J.C., Davidson, C.J., & Pardyjak, E.R. (2007). Understanding sprint-cycling performance, the integration of muscle power, resistance, and modelling. International Journal of Sports Physiology and Performance, 2(1), 5–21.
[6] Gu B., Dominic J., Lai J. S. and Liu C., (2013) ,High Boost Ratio Hybrid Transformer DC-DC Converter For Photovoltaic Module Applications, IEEE Trans Power Electron, 28(4),2048-2058.
[7] Kumary K. S. Revathi B., (2015), High Boost Ratio Hybrid Transformer DC-DC Converter For PV Grid Applications,, IJSR, 4(3), 1711-1714.
[8] Kumar V. H, Sundar K. S., (2016), Optimized Magnetics And Improved Power Devices Utilization For PV Modules By Using Hybrid Transformer ZVS/ZCS DC-DC Converter, IJMETMR, 03(06).
[9] Kanimozhi S., Dr. V. R. (2014),Implementation Of A Non-Isolated, High Gain ZVS/ZCS DC-DC Converter,, IJETAE, 4(5), May 2014, 568-575.
[10] Bukya R.,Design Of Modified Single Input Multiple Output Dc-Dc Converter,, IJCSMC, 3(10), 373-379.